2012-05-07 // LSI 3ware RAID controller: "Parameter not changeable"
I upgraded the OS of two servers last weekend. The planned downtime was also used to install LSI 3ware 9650SE-4LPML RAID controllers plus Battery Backup Unit (BBU). The BBU enables the controller to keep the write cache during a power failure. However, I was not able to create a RAID array with “Write Cache: enabled” on one system. I always got the message “Parameter not changeable” when the configuration was stored.
The solution was simple: wait. The Battery Backup Unit (BBU) on the system was not charged enough, therefore the controller denied enabling the “Write Cache” setting. So if you get the message “Parameter not changeable” when configuring a LSI 3ware Raid Controller, check if the “Write Cache” setting is the root of it and if a charging or failed BBU caused it. You can check the BBU status in the Controller BIOS Setup (I found “BBU Ready: no” in “Information→Battery”).
Comments
Leave a comment…
- E-Mail address will not be published.
- Formatting:
//italic// __underlined__
**bold**''preformatted''
- Links:
[[http://example.com]]
[[http://example.com|Link Text]] - Quotation:
> This is a quote. Don't forget the space in front of the text: "> "
- Code:
<code>This is unspecific source code</code>
<code [lang]>This is specifc [lang] code</code>
<code php><?php echo 'example'; ?></code>
Available: html, css, javascript, bash, cpp, … - Lists:
Indent your text by two spaces and use a * for
each unordered list item or a - for ordered ones.
THank you for this post. It really helped me with a used server that i got that has this raid card in it. now i know i need to get the battery replaced and how to work around it so i can setup my file server